Key Specifications:

Measurement Range: 0-2.54mm (0-100 mils)

Output: -2 to -18VDC linear analog signal

Sensitivity: 8.0mV/µm (200mV/mil)

Frequency Response: DC to 10kHz

Power Supply: -24VDC ±10%

Construction Features:

8mm diameter probe tip

316 stainless steel housing

M10×1 mounting thread

Integral armored cable (standard length varies)

Performance Characteristics:

±1% linearity of full scale

0.1µm resolution

AISI 4140 steel target standard

20g vibration resistance

Environmental Ratings:

Operating temperature: -30°C to +120°C

Storage temperature: -40°C to +150°C

Typical Applications:

Turbine shaft monitoring

Compressor vibration measurement

Rotor position detection

API 670 compliant machinery protection systems

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
1. General Parameters
Model: PR6423/010-100

Type: Non-contact inductive displacement probe

Technology: Eddy current principle

Application: Industrial machinery vibration monitoring

Compliance: API 670 Standard (Machinery Protection Systems)

2. Electrical Characteristics
Power Supply: -24 VDC ±10%

Output Signal: -2 to -18 VDC (gap proportional)

Sensitivity: 8.0 mV/µm (200 mV/mil)

Frequency Response: 0-10 kHz (±3 dB)

Current Draw: 4-8 mA (typical)

3. Mechanical Specifications
Measurement Range: 0-100 mils (0-2.54 mm)

Probe Diameter: 8 mm (standard)

Thread Size: M10×1 metric

Housing Material: 316 Stainless Steel

Cable Termination: Integral armored cable

4. Performance Data
Linearity: ±1% of full scale

Resolution: 0.1 µm

Target Material: Carbon steel (AISI 4140 standard)

Minimum Target Size: 24 mm (3× probe diameter)

5. Environmental Specifications
Operating Temperature: -30°C to +120°C

Storage Temperature: -40°C to +150°C

Vibration Resistance: 20g (10-2000 Hz)

Shock Resistance: 100g (11ms half-sine)

6. Ordering Information
"010" Prefix: Indicates specific product variant

"100" Suffix: Denotes 100 mils (2.54 mm) measurement range

7. Typical Applications
Turbine shaft radial position monitoring

Compressor vibration measurement

Generator air gap monitoring

Rotating machinery protection systems

8. Installation Notes
Requires CON010 or equivalent signal conditioner

Optimal mounting distance: 50-60% of full range

Must be calibrated for specific target material

Proper grounding required for signal integrity

9. Accessories & Compatibility
Matching Extension Cables: CON021 (21m), CON050 (50m)

Signal Conditioners: CON010, DM6000 series

Monitoring Systems: Bently Nevada 3500/3300 series