Products
Products
home
PR6423/00R-010

Key Features:
Operating Principle: Eddy current technology for precise gap measurement.

Output Signal: -2 to -20V DC (linear with displacement).

Sensitivity: Typically 8 mV/µm (or as per -010 calibration).

Measurement Range: Up to 1.0 mm (1000 µm) depending on setup.

Frequency Response: 0–10 kHz, suitable for dynamic vibration monitoring.

Robust Design: Operates in harsh environments (-30°C to +120°C).

Standard Probe Diameter: 8 mm.

Typical Applications:
Shaft vibration monitoring in power plants and industrial machinery.

Axial position measurement (thrust monitoring).

Condition monitoring systems (compatible with EPRO MMS6000 and other protection systems).

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
General Specifications:
Type: Eddy Current / Proximity Sensor (Non-Contact Displacement Measurement)

Application: Vibration and displacement monitoring in rotating machinery (e.g., turbines, compressors, motors)

Electrical Parameters:
Operating Voltage: Typically -24V DC (for most EPRO sensors, confirm with datasheet)

Output Signal: -2 to -20V DC (linear, proportional to gap distance)

Sensitivity: 8 mV/µm (standard for -010 suffix, but verify for exact model)

Measurement Range: 0 to 1.0 mm (1000 µm) or similar (depends on probe and setup)

Frequency Response: 0 to 10 kHz (typical for eddy current sensors)

Mechanical/Environmental:
Operating Temperature: -30°C to +120°C (for sensor head, higher with extension cables)

Cable Length: Typically 5m or 9m (integrated or connectorized options)

Probe Diameter: 8 mm (standard for PR6423 series)

Compatibility: Works with EPRO CON 011 or CON 021 connectors.

Calibration & Setup:
Target Material: Ferrous steel (requires calibration for other materials).

Linear Range: Center 60% of nominal range (e.g., 0.3–0.7 mm for 1mm range).