P0926JMA
Product Type Gauge Pressure Transmitter Measurement Principle Advanced sensor (e.g., Silicon Resonant) Output Signal 4-20 mA analog output with HART® Protocol Accuracy High, typically ±0.075% of span Pressure Range (URL) Example: 0-1600 kPa (based on code J) Process Connection Flush-mounted diaphragm (based on code M) Wetted Parts Material 316L Stainless Steel (based on code A) Power Supply 2-wire, 12-45 VDC (loop-powered) Operating Temperature -40°C to +85°C (ambient) Protection Rating NEMA 4X / IP67

More details >> Request a Quote >>
FOXBORO
875EC-J1F
Product Type Compact Magnetic Flowmeter (Integrated Transmitter and Tube) Measurement Principle Faraday's Law of Electromagnetic Induction Measured Media Electrically conductive liquids (typically with a conductivity > 5 μS/cm) Line Size 3-inch (DN80), based on code J Liner Material PTFE (Teflon®), based on code 1 Electrode Material 316L Stainless Steel, based on code F Accuracy Typical: ±0.5% of rate Output Signal 4-20 mA analog, pulse/frequency, typically with HART® Protocol Power Supply 100-240 VAC or 24 VDC (dependent on specific order code) Protection Rating Typically NEMA 4X / IP67 for field mounting

More details >> Request a Quote >>
FOXBORO
P0914LV
Model Number P0914LV Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive) Output Signal 4-20 mA analog output with HART® Protocol for digital communication. Accuracy High accuracy. For low-pressure "LV" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span. Pressure Range (URL) The "LV" code is critical and typically indicates a low pressure range. The "14" in P0914LV often correlates to a specific range, such as 0-14 kPa (0-2 psi, 0-56 inches of water column). Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases. Wetted Parts Material 316L Stainless Steel is standard. Power Supply Standard 2-wire, 12-45 VDC loop-powered operation. Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options. Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).

More details >> Request a Quote >>
FOXBORO
IPM2-P0904HA REV.A
Product Type Rack-mounted Intelligent Pressure Module Integrated System Foxboro I/A Series DCS Measurement Type Differential Pressure (DP) Typical Range (URL) Example: 0-400 inH₂O (approx. 0-100 kPa) - specific to the H code. Accuracy Very high, typically better than ±0.1% of span. Output Signal Digital communication directly to the I/A Series controller via the system's backplane or proprietary bus. Power Supply Powered via the I/A Series rack backplane. Process Connection External wiring terminals for connecting wires from the field (e.g., from a remote seal or impulse lines). Operating Temperature Designed for a controlled cabinet environment. Primary Application Flow Measurement (with primary elements like orifice plates) and Level Measurement.

More details >> Request a Quote >>
FOXBORO
AD207AU
Model Number AD207AU Function Type Dual-Channel Analog Signal Isolator / Converter Input Signal According to Foxboro's naming convention, "A" typically stands for a DC Current Input (e.g., 4-20 mA). Output Signal According to Foxboro's naming convention, "U" typically stands for a DC Voltage Output (e.g., 1-5 VDC, 0-10 VDC). Number of Channels 2 independent channels (as indicated by the "AD207" base model). Power Supply Requires an external power source, typically 24 VDC. Isolation Channel-to-channel isolation and channel-to-power supply isolation (typically 1500 VAC). Accuracy High typical accuracy, e.g., ±0.1% of span. Input Burden The voltage drop caused by the input current is typically very low (e.g., <3V). Voltage Output Load The voltage output can typically drive a minimum load resistance (e.g., 1 kΩ). Response Time Very fast, typically less than 100 ms. Operating Temperature -20°C to +70°C (standard industrial range). Mounting Standard 35mm DIN rail mounting. Certifications Typically carries international certifications like CE, ATEX, IECEx, FM for use in hazardous areas.

More details >> Request a Quote >>
FOXBORO
P0800DV
Model Number P0800DV Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Stable semiconductor technology (e.g., piezoresistive silicon sensor) Output Signal 4-20 mA analog output, often with HART® Protocol for digital communication. Accuracy Good industrial accuracy, typically ±0.25% of span (including hysteresis and repeatability). This is a key differentiator from more premium models. Pressure Ranges (URL) The "DV" suffix typically corresponds to a medium to high pressure range. A common example is 0-400 bar (0-6000 psi). The exact range is defined by the ordering code. Process Connection Standard: 1/2-14 NPT internal thread. Wetted Parts Material 316L Stainless Steel is standard for the diaphragm and process connections. Power Supply 2-wire, 12-45 VDC (loop-powered). Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options. Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).

More details >> Request a Quote >>
FOXBORO
IDP05S-T22B01FA-M2L1
Product Type Differential Pressure Transmitter with Remote Seal System Measurement Principle Piezoresistive Silicon Sensor Output Signal 4-20 mA DC, 2-wire, Loop-powered, with HART Protocol Sensor Range (URL) Differential Pressure: 0-100 kPa (based on T22 code) Accuracy Typical: ±0.1% of span Wetted Parts Material Diaphragm: 316L Stainless Steel Filling Fluid Silicone Oil (standard type) Remote Seal Style Flush Mounted (ideal for viscous or clogging media) Electrical Connection 1/2" NPT Conduit Protection Rating NEMA 4X / IP67

More details >> Request a Quote >>
FOXBORO
P0916EP
Model Number P0916EP Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive) Output Signal 4-20 mA analog output with HART® Protocol for digital communication. Accuracy High accuracy. For low-pressure "EP" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span. Pressure Range (URL) The "EP" code is critical and typically indicates a very low pressure range. A common example for an EP range is 0-1.6 kPa (0-16 mbar, 0-6.4 inH₂O). The "16" in P0916EP often correlates to this specific range. Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases. Wetted Parts Material 316L Stainless Steel is standard. Power Supply Standard 2-wire, 12-45 VDC loop-powered operation. Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options. Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).

More details >> Request a Quote >>
FOXBORO
AD202MR
Model Number AD202MR Function Type Single-Channel RTD Input Isolator/Converter Input Signal RTD (e.g., Pt100). Supports 2-wire, 3-wire, or 4-wire connection (dependent on exact model configuration). Output Signal 4-20 mA analog current output, linearly proportional to the temperature. Number of Channels 1 Isolation Input/Output/Power Supply triple-way isolation (typically 1500 VAC). This prevents ground loops and noise. Power Supply Requires an external power source, typically 24 VDC. Accuracy High typical accuracy, e.g., ±0.1% of span. Load Capacity The 4-20 mA output can typically drive a load up to 600 Ω. RTD Types Configurable for various types (e.g., Pt100, Pt500, Ni120) with adjustable temperature spans. Operating Temperature -20°C to +70°C (standard industrial range). Mounting Standard 35mm DIN rail mounting. Certifications Typically carries CE, ATEX (for hazardous areas), FM, IECEx certifications.

More details >> Request a Quote >>
FOXBORO
P0972QL
Model Number P0972QL Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Silicon Resonant Sensor Output Signal 4-20 mA analog output with superimposed HART® Protocol for digital communication. Accuracy High accuracy, typically ±0.075% of the Upper Range Limit (URL) for most of its range. (The "QL" often denotes a range that supports this high accuracy). Long-Term Stability Excellent, typically ±0.1% of URL per 12 months. Pressure Ranges (URL) The "QL" suffix specifically indicates a different Upper Range Limit than the "QR" model. For example, while "QR" might cover a very high range, "QL" could indicate a lower or medium pressure range (e.g., a common QL range is 0-100 kPa / 0-15 psi). The exact value must be confirmed via the datasheet or nameplate. Process Connection Standard: 1/2-14 NPT internal thread. Wetted Parts Material 316L Stainless Steel (standard for diaphragm and process connections). Power Supply 2-wire, 12-45 VDC (loop-powered). Operating Temperature Electronics: -40°C to +85°C (-40°F to 185°F). Process Media: -40°C to +125°C (-40°F to 257°F). Protection Rating NEMA 4X / IP67 (weatherproof, dust-tight, and corrosion-resistant).

More details >> Request a Quote >>