Technical Specifications
Parameter Specification
Operating Voltage 9-17.5V DC (bus-powered)
Protection Current 450mA per channel (configurable)
Insertion Loss <0.05dB @ 31.25kHz
Response Time 800ns (typical)
Isolation 1500V DC (channel-to-channel)
Certifications ATEX, IECEx, UL, CSA
Typical Applications
✔ Oil & gas production facilities
✔ Chemical processing plants
✔ Pharmaceutical manufacturing
✔ Power generation systems
✔ Food & beverage processing
Key Features & Benefits
Reliable Power Conditioning
Output: 20V DC (FOUNDATION Fieldbus compliant)
Current limit: 350mA (field side)
1500V DC galvanic isolation
Robust Protection
Short-circuit and overload protection
Reverse polarity protection
Surge protection (6kV/3kA)
Industrial Design
Operating temperature: -40°C to +85°C
DIN-rail mountable (35mm)
Aluminum housing for heat dissipation
Easy Integration
Plug-and-play installation
LED status indicators
Compatible with major DCS systems
Technical Specifications
Parameter Specification
Input Voltage 18-32V DC
Output Voltage 20V DC (±1%)
Maximum Current 350mA
Isolation Voltage 1500V DC
Certifications ATEX, IECEx, UL, CSA
Typical Applications
✔ Oil & gas processing plants
✔ Chemical production facilities
✔ Pharmaceutical manufacturing
✔ Power generation systems
✔ Water treatment plants
Key Features & Benefits
Precision Power Conditioning
Stabilized 20V DC output (±0.5%)
400mA current capacity (field side)
Active current limiting with fast recovery
Advanced Signal Integrity
<0.1dB signal attenuation
Integrated low-pass filtering (45kHz cutoff)
2000V DC galvanic isolation
Smart Diagnostics
Real-time voltage/current monitoring
Waveform capture and analysis
Predictive failure detection
Industrial Robustness
-40°C to +85°C operating range
IP40-rated aluminum enclosure
DIN-rail mounting (35mm)
Technical Specifications
Parameter Specification
Input Voltage 18-32V DC
Output Voltage 20V DC (±0.5%)
Maximum Current 400mA (field side)
Isolation 2000V DC (input-to-output)
Diagnostic Interface Modbus TCP, USB 2.0
Certifications ATEX, IECEx, UL, CSA, SIL2
Typical Applications
✔ Offshore oil platforms
✔ Petrochemical refineries
✔ Pharmaceutical batch processes
✔ Power plant control systems
✔ Food & beverage production
Key Features & Benefits
High-Capacity Power Conditioning
60V DC output (FOUNDATION Fieldbus compliant)
500mA current capacity (field side)
2000V DC galvanic isolation
Advanced Protection
Instantaneous short-circuit protection (<1μs)
Overvoltage and reverse polarity protection
8kV surge protection (ANSI/IEEE C62.41)
Industrial-Grade Construction
-40°C to +85°C operating range
IP66-rated aluminum enclosure
DIN-rail or panel mounting options
Smart Diagnostics
LED status indicators (power/segment health)
Remote monitoring capability
Predictive failure detection
Technical Specifications
Parameter Specification
Input Voltage 24V DC (18-32V range)
Output Voltage 60V DC (±1%)
Maximum Current 500mA continuous
Isolation 2000V DC (input-to-output)
Response Time <1μs (short-circuit)
Certifications ATEX, IECEx, UL, CSA, SIL2
Typical Applications
✔ Oil & gas production facilities
✔ Chemical processing plants
✔ Power generation systems
✔ Pharmaceutical manufacturing
✔ Water treatment automation
Key Features & Benefits
Precision Power Regulation
65V DC output (FF H1 compliant)
450mA current capacity (field side)
±0.5% voltage regulation accuracy
Advanced Protection System
1500V DC galvanic isolation
<1μs short-circuit response
6kV/3kA surge protection
Industrial Durability
-40°C to +85°C operating range
IP40-rated metal housing
DIN-rail mountable (35mm)
Smart Diagnostics
Dual-color LED status indicators
Remote monitoring capability
Built-in self-test function
Technical Specifications
Parameter Specification
Input Voltage 18-32V DC
Output Voltage 65V DC (±0.5%)
Maximum Current 450mA
Isolation 1500V DC
Response Time <1μs (short-circuit)
Certifications ATEX, IECEx, UL, CSA
Typical Applications
✔ Oil & gas processing plants
✔ Chemical production facilities
✔ Power generation systems
✔ Pharmaceutical manufacturing
✔ Water treatment plants
Key Features & Benefits
Precision Power Regulation
19.5V DC output (FF H1 compliant)
350mA current capacity
±0.5% voltage regulation accuracy
Advanced Protection Features
1500V DC galvanic isolation
<1μs short-circuit response
Reverse polarity protection
Industrial-Grade Design
-40°C to +85°C operating range
IP40-rated aluminum enclosure
Compact DIN-rail mounting (35mm)
Enhanced Diagnostics
LED status indicators (power/segment health)
Remote monitoring capability
Built-in self-test functionality
Technical Specifications
Parameter Specification
Input Voltage 18-32V DC
Output Voltage 19.5V DC (±0.5%)
Maximum Current 350mA
Isolation 1500V DC
Response Time <1μs (short-circuit)
Certifications ATEX, IECEx, UL, CSA
Typical Applications
✔ Oil & gas processing facilities
✔ Chemical production plants
✔ Power generation systems
✔ Pharmaceutical manufacturing
✔ Water treatment automation
Technical Specifications
Parameter Specification
Voltage Range 9-32V DC
Current Capacity 500mA per segment
Isolation 2000V DC (segment-to-segment)
Switchover Time <1ms
Certifications ATEX, IECEx, SIL2, UL, CSA
Typical Applications
✔ Offshore oil platforms
✔ Nuclear power plants
✔ Pharmaceutical batch processes
✔ Chemical reactor control
✔ Critical pipeline operations
Technical Specifications
Parameter Specification
Protocol FOUNDATION Fieldbus H1 (IEC 61158-2)
Channels 2 independent H1 ports
Device Support 32 devices per segment
Isolation 2000V AC (channel-to-system)
Certifications ATEX, IECEx, SIL2, UL, CSA
Typical Applications
✔ Oil & gas production facilities
✔ Chemical batch processes
✔ Pharmaceutical manufacturing
✔ Power plant control systems
✔ Water treatment automation