Products
Products
home
HoneyWell
900P01-0301=2
Honeywell 900P01-0301=2
Function: Redundancy-Ready CPU Module for HC900 Process Control Systems.

Core Role:

Primary processor for executing control logic (PID, sequencing) in HC900 racks.

Supports hot-swap N+1 redundancy for fail-safe operation.

Key Specs:

I/O Capacity: Up to 16 modules (256 points).

Communications: Modbus TCP (Ethernet), Modbus RTU/ASCII (RS-232/485).

Environment: -40°C to +70°C industrial rating.

Integration:

Requires HC900 C70/C75 chassis; compatible with analog/digital I/O modules.

More details >> Request a Quote >>
HoneyWell
900C75-0460=2
Honeywell 900C75-0460=2
Function: 120W Power Supply Module for HC900 Process Control Systems.

Key Features:

Input: 85–265 VAC (50/60 Hz) or 88–300 VDC (universal).

Output: 24 VDC, 5A (regulated, 120W max).

Redundancy: Supports N+1 backup with identical modules.

Protections: Short-circuit, over-voltage, and thermal shutdown.

Compatibility:

Designed for HC900 C50/C70/C75 racks.

Robust Design:

Operates in -40°C to +70°C harsh environments.

Certifications: UL, CE, ATEX Zone 2.

More details >> Request a Quote >>
HoneyWell
HC900RR0-0101
Honeywell HC900RR0-0101
Function: CPU Module for Honeywell’s HC900 Hybrid Process Control System.

Core Role:

Acts as the central processor for HC900 racks, executing control logic (PID, sequencing, etc.).

Supports 16 I/O modules (max 256 points) for analog/digital signals.

Key Features:

Communications: Ethernet (Modbus TCP), RS-232/485 (Modbus RTU/ASCII), embedded web server.

Robust Operation: -40°C to +70°C industrial temperature range.

Power: 24 VDC (±10%).

More details >> Request a Quote >>
HoneyWell
XF524A
Honeywell XF524A
Function: Dual-Circuit Monitor Module for conventional fire alarm systems.

Key Features:

Monitors two independent dry-contact devices (e.g., flow switches, tamper switches, door holders).

Input Voltage: 15–32 VDC (regulated).

Low Power: Standby ≤1.5 mA; alarm ≤6 mA per circuit.

Wiring: Class A (Style Z) or Class B (Style Y) supervision.

More details >> Request a Quote >>
HoneyWell
XF521A
Honeywell XF521A
Function: Dry Contact Monitor Module for conventional fire alarm systems.

Key Features:

Supervises dry-contact devices (e.g., door holders, sprinkler flow switches, HVAC shutdowns).

Input Voltage: 15–32 VDC (regulated).

Low Power: Standby current ≤1.5 mA; alarm current ≤6 mA.

Wiring Styles: Supports Class A (Style Z) or Class B (Style Y) supervision.

Compatibility:

Works with Notifier® fire panels (e.g., NFS2-640, AFP-1010/AFP-4000).

Certifications: UL 864, ULC, CE.

More details >> Request a Quote >>
HoneyWell
XC5010C
Honeywell XC5010C
Function: Conventional Fire Alarm Zone Module for expanding detection capacity in fire systems.

Key Features:

Input Voltage: 15–32 VDC (regulated power).

Load Capacity: Supports 50 detectors + accessories (e.g., manual call points, monitors).

Compatibility: Integrates with Notifier® NFS2-3030/C, AFP-1010, and similar panels.

Wiring: Class A (Style D) or Class B (Style B) configurations.

Environmental:

Operating Temp: -10°C to +55°C (14°F to 131°F).

Certifications: UL 864, ULC, CE.

More details >> Request a Quote >>
HoneyWell
DC3300
Honeywell DC3300
Core Role: Digital field controller for industrial automation and building management systems (BMS).

Key Features:

Protocols: Modbus RTU/TCP, BACnet MS/TP, Ethernet/IP.

I/O Flexibility: Modular expansion (supports up to 32 modules).

Robust Operation: -40°C to +70°C range; 10–90% humidity tolerance.

Processing: 32-bit RISC CPU with embedded logic (Spyder® programming).

Typical Use:

HVAC control, energy management, and equipment monitoring in commercial/industrial facilities.

More details >> Request a Quote >>
HoneyWell
51454220-176
Honeywell 51454220-176
Function: 16-channel Digital Input Module for Honeywell Experion® PKS/LX control systems.

Key Features:

Isolated Inputs: 24 VDC (sink/source configurable) with 1500 VAC channel isolation.

High-Speed: ≤5 ms response time.

Robust Design: Operates in -40°C to +70°C harsh environments.

Certifications: ATEX/IECEx, SIL 2 (IEC 61508).

Integration:

Mounts in Experion LX I/O chassis; interfaces with C300 controllers.

Typical Use:

Monitoring switches/sensors in oil & gas, chemical, or power plants.

More details >> Request a Quote >>
HoneyWell
SPXCDXSB1SS
Danfoss SPXCDXSB1SS
Function: Electronic Expansion Valve (EEV) for precise refrigerant flow control in cooling systems.

Key Features:

Refrigerants: Compatible with R134a, R404A, R410A, R407C, R507.

Robust Operation: Withstands -40°C to +125°C and 42 bar (608 psi).

Control: 12 VDC powered; accepts PWM or 0–10 VDC signals.

Connection: 1/2" SAE flare.

More details >> Request a Quote >>
HoneyWell
SPXCDXSFXSS
Danfoss SPXCDXSFXSS
Function: Electronic Expansion Valve (EEV) for precise refrigerant flow control in cooling systems.

Key Features:

Compatible Refrigerants: R134a, R404A, R410A, R507, R407C.

Robust Design: Operates at -40°C to +125°C and up to 42 bar (608 psi).

Control: PWM or 0–10 VDC input signal.

Connection: 1/2" SAE flare.

More details >> Request a Quote >>
1 2
··· ···